Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 132
Filtrar
1.
Plast Reconstr Surg ; 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38351515

RESUMO

Preoperative CT angiography (CTA) is increasingly performed prior to perforator flap-based reconstruction. However, radiological 2D thin-slices do not allow for intuitive interpretation and translation to intraoperative findings. 3D volume rendering has been used to alleviate the need for mental 2D-to-3D abstraction. Even though volume rendering allows for a much easier understanding of anatomy, it currently has limited utility as the skin obstructs the view of critical structures. Using free, open-source software, we introduce a new skin-masking technique that allows surgeons to easily create a segmentation mask of the skin that can later be used to toggle the skin on and off. Additionally, the mask can be used in other rendering applications. We use Cinematic Anatomy for photorealistic volume rendering and interactive exploration of the CTA with and without skin. We present results from using this technique to investigate perforator anatomy in deep inferior epigastric perforator flaps and demonstrate that the skin-masking workflow is performed in less than 5 minutes. In Cinematic Anatomy, the view onto the abdominal wall and especially onto perforators becomes significantly sharper and more detailed when no longer obstructed by the skin. We perform a virtual, partial muscle dissection to show the intramuscular and submuscular course of the perforators. The skin-masking workflow allows surgeons to improve arterial and perforator detail in volume renderings easily and quickly by removing skin and could alternatively also be performed solely using open-source and free software. The workflow can be easily expanded to other perforator flaps without the need for modification.

2.
Plast Reconstr Surg ; 153(2): 524-534, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-37092985

RESUMO

BACKGROUND: Autologous breast reconstruction yields improved long-term aesthetic results but requires increased resources of practitioners and hospital systems. Innovations in radiographic imaging have been increasingly used to improve the efficiency and success of free flap harvest. Augmented reality affords the opportunity to superimpose relevant imaging on a surgeon's native field of view, potentially facilitating dissection of anatomically variable structures. To validate the spatial fidelity of augmented reality projections of deep inferior epigastric perforator flap-relevant anatomy, comparisons of three-dimensional (3D) models and their virtual renderings were performed by four independent observers. Measured discrepancies between the real and holographic models were evaluated. METHODS: The 3D-printed models of deep inferior epigastric perforator flap-relevant anatomy were fabricated from computed tomographic angiography data from 19 de-identified patients. The corresponding computed tomographic angiography data were similarly formatted for the Microsoft HoloLens to generate corresponding projections. Anatomic points were initially measured on 3D models, after which the corresponding points were measured on the HoloLens projections from two separate vantage points (V1 and V2). Statistical analyses, including generalized linear modeling, were performed to characterize spatial fidelity regarding translation, rotation, and scale of holographic projections. RESULTS: Among all participants, the median translational displacement at corresponding points was 9.0 mm between the real-3D model and V1, 12.1 mm between the 3D model and V2, and 13.5 mm between V1 and V2. CONCLUSION: Corresponding points, including topography of perforating vessels, for the purposes of breast reconstruction can be identified within millimeters, but there remain multiple independent contributors of error, most notably the participant and location at which the projection is perceived.


Assuntos
Realidade Aumentada , Mamoplastia , Retalho Perfurante , Humanos , Retalho Perfurante/irrigação sanguínea , Mamoplastia/métodos , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X/métodos , Artérias Epigástricas
3.
IEEE Trans Vis Comput Graph ; 29(11): 4494-4502, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37782607

RESUMO

This paper investigates the accuracy of Augmented Reality (AR) technologies, particularly commercially available optical see-through displays, in depicting virtual content inside the human body for surgical planning. Their inherent limitations result in inaccuracies in perceived object positioning. We examine how occlusion, specifically with opaque surfaces, affects perceived depth of virtual objects at arm's length working distances. A custom apparatus with a half-silvered mirror was developed, providing accurate depth cues excluding occlusion, differing from commercial displays. We carried out a study, contrasting our apparatus with a HoloLens 2, involving a depth estimation task under varied surface complexities and illuminations. In addition, we explored the effects of creating a virtual "hole" in the surface. Subjects' depth estimation accuracy and confidence were a ssessed. Results showed more depth estimation variation with HoloLens and significant depth error beneath complex occluding surfaces. However, creating a virtual hole significantly reduced depth errors and increased subjects' confidence, irrespective of accuracy enhancement. These findings have important implications for the design and use of mixed-reality technologies in surgical applications, and industrial applications such as using virtual content to guide maintenance or repair of components hidden beneath the opaque outer surface of equipment. A free copy of this paper and all supplemental materials are available at https://bit.ly/3YbkwjU.


Assuntos
Braço , Realidade Aumentada , Humanos , Gráficos por Computador , Interface Usuário-Computador , Percepção de Profundidade
4.
Otolaryngol Head Neck Surg ; 169(4): 1083-1085, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36934457

RESUMO

Head and neck surgeons often have difficulty in relocating sites of positive margins due to the complex 3-dimensional (3D) anatomy of the head and neck. We introduce a new technique where resection specimens are 3D scanned with a smartphone, annotated in computer-assisted design software, and immediately visualized on augmented reality (AR) glasses. The 3D virtual specimen can be accurately superimposed onto surgical sites for orientation and sizing applications. During an operative workshop, a surgeon using AR glasses projected virtual, annotated specimen models back into the resection bed onto a cadaver within approximately 10 minutes. Colored annotations can correspond with pathologic annotations and guide the orientation of the virtual 3D specimen. The model was also overlayed onto a flap harvest site to aid in reconstructive planning. We present a new technique allowing interactive, sterile inspection of tissue specimens in AR that could facilitate communication among surgeons and pathologists and assist with reconstructive surgery.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Humanos , Software , Cirurgia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Cabeça , Imageamento Tridimensional
5.
J Nucl Med ; 64(4): 592-597, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36328488

RESUMO

Focal therapy for localized prostate cancer (PC) using high-intensity focused ultrasound (HIFU) is gaining in popularity as it is noninvasive and associated with fewer side effects than standard whole-gland treatments. However, better methods to evaluate response to HIFU ablation are an unmet need. Prostate-specific membrane antigen (PSMA) and gastrin-releasing peptide receptors are both overexpressed in PC. In this study, we evaluated a novel approach of using both 68Ga-RM2 and 68Ga-PSMA11 PET/MRI in each patient before and after HIFU to assess the accuracy of target tumor localization and response to treatment. Methods: Fourteen men, 64.5 ± 8.0 y old (range, 48-78 y), with newly diagnosed PC were prospectively enrolled. Before HIFU, the patients underwent prostate biopsy, multiparametric MRI, 68Ga-PSMA11, and 68Ga-RM2 PET/MRI. Response to treatment was assessed at a minimum of 6 mo after HIFU with prostate biopsy (n = 13), as well as 68Ga-PSMA11 and 68Ga-RM2 PET/MRI (n = 14). The SUVmax and SUVpeak of known or suspected PC lesions were collected. Results: Pre-HIFU biopsy revealed 18 cancers, of which 14 were clinically significant (Gleason score ≥ 3 + 4). Multiparametric MRI identified 18 lesions; 14 of them were at least score 4 in the Prostate Imaging-Reporting and Data System. 68Ga-PSMA11 and 68Ga-RM2 PET/MRI each showed 23 positive intraprostatic lesions; 21 were congruent in 13 patients, and 5 were incongruent in 5 patients. Before HIFU, 68Ga-PSMA11 identified all target tumors, whereas 68Ga-RM2 PET/MRI missed 2 tumors. After HIFU, 68Ga-RM2 and 68Ga-PSMA11 PET/MRI both identified clinically significant residual disease in 1 patient. Three significant ipsilateral recurrent lesions were identified, whereas 1 was missed by 68Ga-PSMA11. The pretreatment level of prostate-specific antigen decreased significantly after HIFU, by 66%. Concordantly, the pretreatment SUVmax decreased significantly after HIFU for 68Ga-PSMA11 (P = 0.001) and 68Ga-RM2 (P = 0.005). Conclusion: This pilot study showed that 68Ga-PSMA11 and 68Ga-RM2 PET/MRI identified the target tumor for HIFU in 100% and 86% of cases, respectively, and accurately verified response to treatment. PET may be a useful tool in the guidance and monitoring of treatment success in patients receiving focal therapy for PC. These preliminary findings warrant larger studies for validation.


Assuntos
Tratamento por Ondas de Choque Extracorpóreas , Neoplasias da Próstata , Masculino , Humanos , Radioisótopos de Gálio , Projetos Piloto , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/terapia , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
6.
J Nucl Med ; 64(5): 744-750, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36396456

RESUMO

Targeting of lesions seen on multiparametric MRI (mpMRI) improves prostate cancer (PC) detection at biopsy. However, 20%-65% of highly suspicious lesions on mpMRI (PI-RADS [Prostate Imaging-Reporting and Data System] 4 or 5) are false-positives (FPs), while 5%-10% of clinically significant PC (csPC) are missed. Prostate-specific membrane antigen (PSMA) and gastrin-releasing peptide receptors (GRPRs) are both overexpressed in PC. We therefore aimed to evaluate the potential of 68Ga-PSMA11 and 68Ga-RM2 PET/MRI for biopsy guidance in patients with suspected PC. Methods: A highly selective cohort of 13 men, aged 58.0 ± 7.1 y, with suspected PC (persistently high prostate-specific antigen [PSA] and PSA density) but negative or equivocal mpMRI results or negative biopsy were prospectively enrolled to undergo 68Ga-PSMA11 and 68Ga-RM2 PET/MRI. PET/MRI included whole-body and dedicated pelvic imaging after a delay of 20 min. All patients had targeted biopsy of any lesions seen on PET followed by standard 12-core biopsy. The SUVmax of suspected PC lesions was collected and compared with gold standard biopsy. Results: PSA and PSA density at enrollment were 9.8 ± 6.0 (range, 1.5-25.5) ng/mL and 0.20 ± 0.18 (range, 0.06-0.68) ng/mL2, respectively. Standardized systematic biopsy revealed a total of 14 PCs in 8 participants: 7 were csPC and 7 were nonclinically significant PC (ncsPC). 68Ga-PSMA11 identified 25 lesions, of which 11 (44%) were true-positive (TP) (5 csPC). 68Ga-RM2 showed 27 lesions, of which 14 (52%) were TP, identifying all 7 csPC and also 7 ncsPC. There were 17 concordant lesions in 11 patients versus 14 discordant lesions in 7 patients between 68Ga-PSMA11 and 68Ga-RM2 PET. Incongruent lesions had the highest rate of FP (12 FP vs. 2 TP). SUVmax was significantly higher for TP than FP lesions in delayed pelvic imaging for 68Ga-PSMA11 (6.49 ± 4.14 vs. 4.05 ± 1.55, P = 0.023) but not for whole-body images, nor for 68Ga-RM2. Conclusion: Our results show that 68Ga-PSMA11 and 68Ga-RM2 PET/MRI are feasible for biopsy guidance in suspected PC. Both radiopharmaceuticals detected additional clinically significant cancers not seen on mpMRI in this selective cohort. 68Ga-RM2 PET/MRI identified all csPC confirmed at biopsy.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Masculino , Humanos , Radioisótopos de Gálio , Antígeno Prostático Específico , Projetos Piloto , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Tomografia por Emissão de Pósitrons/métodos , Biópsia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
7.
J Magn Reson Imaging ; 58(3): 951-962, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36583628

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) may allow for breast cancer screening MRI without a contrast injection. Multishot methods improve prone DWI of the breasts but face different challenges in the supine position. PURPOSE: To establish a multishot DWI (msDWI) protocol for supine breast MRI and to evaluate the performance of supine vs. prone msDWI. STUDY TYPE: Prospective. POPULATION: Protocol optimization: 10 healthy women (ages 22-56), supine vs. prone: 24 healthy women (ages 22-62) and five women (ages 29-61) with breast tumors. FIELD STRENGTH/SEQUENCE: 3-T, protocol optimization msDWI: free-breathing (FB) 2-shots, FB 4-shots, respiratory-triggered (RT) 2-shots, RT 4-shots, supine vs. prone: RT 4-shot msDWI, T2-weighted fast-spin echo. ASSESSMENT: Protocol optimization and supine vs. prone: three observers performed an image quality assessment of sharpness, aliasing, distortion (vs. T2), perceived SNR, and overall image quality (scale of 1-5). Apparent diffusion coefficients (ADCs) in fibroglandular tissue (FGT) and breast tumors were measured. STATISTICAL TESTS: Effect of study variables on dichotomized ratings (4/5 vs. 1/2/3) and FGT ADCs were assessed with mixed-effects logistic regression. Interobserver agreement utilized Gwet's agreement coefficient (AC). Lesion ADCs were assessed by Bland-Altman analysis and concordance correlation (ρc ). P value <0.05 was considered statistically significant. RESULTS: Protocol optimization: 4-shots significantly improved sharpness and distortion; RT significantly improved sharpness, aliasing, perceived SNR, and overall image quality. FGT ADCs were not significantly different between shots (P = 0.812), FB vs. RT (P = 0.591), or side (P = 0.574). Supine vs. prone: supine images were rated significantly higher for sharpness, aliasing, and overall image quality. FGT ADCs were significantly higher supine; lesion ADCs were highly correlated (ρc  = 0.92). DATA CONCLUSION: Based on image quality, supine msDWI outperformed prone msDWI. Lesion ADCs were highly correlated between the two positions, while FGT ADCs were higher in the supine position. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Humanos , Feminino , Estudos Prospectivos , Decúbito Ventral , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Imagem Ecoplanar/métodos
8.
Oral Oncol ; 125: 105702, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34991004

RESUMO

OBJECTIVE: To show that augmented reality (AR) visualization of single-photon emission computed tomography (SPECT)/computed tomography (CT) data in 3D can be used to accurately localize targets in the head and neck region. MATERIALS AND METHODS: Eight head and neck styrofoam phantoms were painted with a mixture of radioactive solution (Tc-99m) detectable with a handheld gamma probe and fluorescent ink visible only under ultraviolet (UV) light to create 10-20 simulated lymph nodes on their surface. After obtaining SPECT/CT images of these phantoms, virtual renderings of the nodes were generated from the SPECT/CT data and displayed using a commercially available AR headset. For each of three physician evaluators, the time required to localize lymph node targets was recorded (1) using the gamma probe alone and (2) using the gamma probe while wearing the AR headset. In addition, the surface localization accuracy when using the AR headset was evaluated by measuring the misalignment between the locations visually marked by the evaluators and the ground truth locations identified using UV stimulation of the ink at the site of the nodes. RESULTS: For all three evaluators, using the AR headset significantly reduced the time to detect targets (P = 0.012, respectively) compared to using the gamma probe alone. The average misalignment between the location marked by the evaluators and the ground truth location was 8.6 mm. CONCLUSION: AR visualization of SPECT/CT data in 3D allows for accurate localization of targets in the head and neck region, and may reduce the localization time of targets.


Assuntos
Realidade Aumentada , Melanoma , Linfonodo Sentinela , Humanos , Melanoma/diagnóstico por imagem , Melanoma/patologia , Melanoma/cirurgia , Biópsia de Linfonodo Sentinela/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos
9.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21268040

RESUMO

Although the emerging SARS-CoV-2 variants of concern (VOC) have shown increasing transmissibility, their role for causing severe disease has not been fully clarified. Here, we studied changes in rates of hospitalisation and severe illness (subjection to high-flow nasal oxygen or admission to an intensive care unit during hospital stay) among all (n=685 891) unvaccinated SARS-CoV-2 positive adults without risk factors in Sweden from November 2020 to September 2021. After adjustment for age, sex, and socio-economic factors, and with November 2020 (non-VOC period) as reference, the odds ratios (OR) for hospitalisation were 1.6-1.7 in March-May 2021 (Alpha VOC dominance) and 2.4-3.0 in June-September 2021 (Delta VOC dominance), and the ORs for severe illness were 1.8-2.1 in March-May 2021 and 3.1-4.7 in June-September 2021. This study shows that unvaccinated adults without risk factors, have had a gradually increased risk for hospital admission and severe illness when infected with the Alpha and Delta VOCs, respectively.

10.
Med Phys ; 48(10): 6069-6079, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34287972

RESUMO

PURPOSE: Almost one in four lumpectomies fails to fully remove cancerous tissue from the breast, requiring reoperation. This high failure rate suggests that existing lumpectomy guidance methods are inadequate for allowing surgeons to consistently identify the proper volume of tissue for excision. Current guidance techniques either provide little information about the tumor position or require surgeons to frequently switch between making incisions and manually probing for a marker placed at the lesion site. This article explores the feasibility of thermo-acoustic ultrasound (TAUS) to enable hands-free localization of metallic biopsy markers throughout surgery, which would allow for continuous visualization of the lesion site in the breast without the interruption of surgery. In a TAUS-based localization system, microwave excitations would be transmitted into the breast, and the amplification in microwave absorption around the metallic markers would generate acoustic signals from the marker sites through the thermo-acoustic effect. Detection and ranging of these signals by multiple acoustic receivers on the breast could then enable marker localization through acoustic multilateration. METHODS: Physics simulations were used to characterize the TAUS signals generated from different markers by microwave excitations. First, electromagnetic simulations determined the spatial pattern of the amplification in microwave absorption around the markers. Then, acoustic simulations characterized the acoustic fields generated from these markers at various acoustic frequencies. TAUS-based one-dimensional (1D) ranging of two metallic markers-including a biopsy marker that is FDA-approved for clinical use-immersed in saline was also performed using a bench-top setup. To perform TAUS acquisitions, a microwave applicator was driven by 2.66 GHz microwave signals that were amplitude-modulated by chirps at the desired acoustic excitation frequencies, and the resulting TAUS signal from the markers was detected by an ultrasonic transducer. RESULTS: The simulation results show that the geometry of the marker strongly impacts the quantity and spatial pattern of both the microwave absorption around the marker and the resulting TAUS signal generated from the marker. The simulated TAUS signal maps and acoustic frequency responses also make clear that the marker geometry plays an important role in determining the overall system response. Using the bench-top setup, TAUS detection and 1D localization of the markers were successfully demonstrated for multiple different combinations of microwave applicator and metallic marker. These initial results indicate that TAUS-based localization of biopsy markers is feasible. CONCLUSIONS: Through microwave excitations and acoustic detection, TAUS can be used to localize metallic biopsy markers. With further development, TAUS opens new avenues to enable a more intuitive lumpectomy guidance system that could help to achieve better lumpectomy outcomes.


Assuntos
Neoplasias da Mama , Mastectomia Segmentar , Acústica , Biópsia , Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Humanos , Ultrassonografia
11.
Magn Reson Med ; 85(2): 709-720, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32783339

RESUMO

PURPOSE: To accelerate and improve multishot diffusion-weighted MRI reconstruction using deep learning. METHODS: An unrolled pipeline containing recurrences of model-based gradient updates and neural networks was introduced for accelerating multishot DWI reconstruction with shot-to-shot phase correction. The network was trained to predict results of jointly reconstructed multidirection data using single-direction data as input. In vivo brain and breast experiments were performed for evaluation. RESULTS: The proposed method achieves a reconstruction time of 0.1 second per image, over 100-fold faster than a shot locally low-rank reconstruction. The resultant image quality is comparable to the target from the joint reconstruction with a peak signal-to-noise ratio of 35.3 dB, a normalized root-mean-square error of 0.0177, and a structural similarity index of 0.944. The proposed method also improves upon the locally low-rank reconstruction (2.9 dB higher peak signal-to-noise ratio, 29% lower normalized root-mean-square error, and 0.037 higher structural similarity index). With training data from the brain, this method also generalizes well to breast diffusion-weighted imaging, and fine-tuning further reduces aliasing artifacts. CONCLUSION: A proposed data-driven approach enables almost real-time reconstruction with improved image quality, which improves the feasibility of multishot DWI in a wide range of clinical and neuroscientific studies.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes
12.
J Magn Reson Imaging ; 53(3): 807-817, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33067849

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) has shown promise to screen for breast cancer without a contrast injection, but image distortion and low spatial resolution limit standard single-shot DWI. Multishot DWI methods address these limitations but introduce shot-to-shot phase variations requiring correction during reconstruction. PURPOSE: To investigate the performance of two multishot DWI reconstruction methods, multiplexed sensitivity encoding (MUSE) and shot locally low-rank (shot-LLR), compared to single-shot DWI in the breast. STUDY TYPE: Prospective. POPULATION: A total of 45 women who consented to have multishot DWI added to a clinically indicated breast MRI. FIELD STRENGTH/SEQUENCES: Single-shot DWI reconstructed by parallel imaging, multishot DWI with four or eight shots reconstructed by MUSE and shot-LLR, 3D T2 -weighted imaging, and contrast-enhanced MRI at 3T. ASSESSMENT: Three blinded observers scored images for 1) general image quality (perceived signal-to-noise ratio [SNR], ghosting, distortion), 2) lesion features (discernment and morphology), and 3) perceived resolution. Apparent diffusion coefficient (ADC) of the lesion was also measured and compared between methods. STATISTICAL TESTS: Image quality features and perceived resolution were assessed with a mixed-effects logistic regression. Agreement among observers was estimated with a Krippendorf's alpha using linear weighting. Lesion feature ratings were visualized using histograms, and correlation coefficients of lesion ADC between different methods were calculated. RESULTS: MUSE and shot-LLR images were rated to have significantly better perceived resolution (P < 0.001), higher SNR (P < 0.005), and a lower level of distortion (P < 0.05) with respect to single-shot DWI. Shot-LLR showed reduced ghosting artifacts with respect to both MUSE (P < 0.001) and single-shot DWI (P < 0.001). Eight-shot DWI had improved perceived SNR and perceived resolution with respect to four-shot DWI (P < 0.005). DATA CONCLUSION: Multishot DWI enables increased resolution and improved image quality with respect to single-shot DWI in the breast. Shot-LLR reconstructs multishot DWI with minimal ghosting artifacts. The improvement of multishot DWI in image quality increases with an increased number of shots. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Artefatos , Feminino , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes
13.
Br J Radiol ; 94(1118): 20201166, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33332980

RESUMO

OBJECTIVE: To compare positive predictive values (PPVs) of clumped vs non-clumped (homogenous and heterogeneous) internal enhancement on MRI detected linear non-mass enhancement (NME) on MRI-guided vacuum-assisted breast biopsy (MRI-VABB). METHODS: With IRB (Institutional Review Board) approval, we retrospectively reviewed 598 lesions undergoing MRI-VABB from January 2015 to April 2018 that showed linear NME. We reviewed the electronic medical records for MRI-VABB pathology, any subsequent surgery and clinical follow-up. The X2 test was performed for univariate analysis. RESULTS: There were 120/598 (20%) linear NME MRI-VABB lesions with clumped (52/120, 43%) vs non-clumped (68/120, 57%) internal enhancement, average size 1.8 cm (range 0.6-7.6 cm). On MRI-VABB, cancer was identified in 22/120 (18%) lesions, ductal carcinoma in situ (DCIS) was found in 18/22 (82%) and invasive cancer in 4 (18%). 3/31 (10%) high-risk lesions upgraded to DCIS at surgery, for a total of 25/120 (21%) malignancies. Malignancy was found in 12/52 (23%) clumped lesions and in 13/68 (19%) of non-clumped lesions that showed heterogeneous (5/13, 38%) or homogenous (8/13, 62%) internal enhancement. The PPV of linear NME with clumped internal enhancement (23.1%) was not significantly different from the PPV of non-clumped linear NME (19.1%) (p = 0.597). The PPV of linear NME lesions <1 cm (33.3%) was not significantly different from the PPV of lesions ≥1 cm (18.6%) (p = 0.157). CONCLUSIONS: Linear NME showed malignancy in 21% of our series. Linear NME with clumped or non-clumped internal enhancement patterns, regardless of lesion size, might need to undergo MRI-VABB in appropriate populations. ADVANCES IN KNOWLEDGE: Evaluation of linear NME lesions on breast MRI focuses especially on internal enhancement pattern.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Mama/patologia , Feminino , Humanos , Biópsia Guiada por Imagem , Pessoa de Meia-Idade , Estudos Retrospectivos , Vácuo
14.
J Magn Reson Imaging ; 53(5): 1594-1605, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33382171

RESUMO

The image quality limitations of echo-planar diffusion-weighted imaging (DWI) are an obstacle to its widespread adoption in the breast. Steady-state DWI is an alternative DWI method with more robust image quality but its contrast for imaging breast cancer is not well-understood. The aim of this study was to develop and evaluate diffusion-weighted double-echo steady-state imaging with a three-dimensional cones trajectory (DW-DESS-Cones) as an alternative to conventional DWI for non-contrast-enhanced MRI in the breast. This prospective study included 28 women undergoing clinically indicated breast MRI and six asymptomatic volunteers. In vivo studies were performed at 3 T and included DW-DESS-Cones, DW-DESS-Cartesian, DWI, and CE-MRI acquisitions. Phantom experiments (diffusion phantom, High Precision Devices) and simulations were performed to establish framework for contrast of DW-DESS-Cones in comparison to DWI in the breast. Motion artifacts of DW-DESS-Cones were measured with artifact-to-noise ratio in volunteers and patients. Lesion-to-fibroglandular tissue signal ratios were measured, lesions were categorized as hyperintense or hypointense, and an image quality observer study was performed in DW-DESS-Cones and DWI in patients. Effect of DW-DESS-Cones method on motion artifacts was tested by mixed-effects generalized linear model. Effect of DW-DESS-Cones on signal in phantom was tested by quadratic regression. Correlation was calculated between DW-DESS-Cones and DWI lesion-to-fibroglandular tissue signal ratios. Inter-observer agreement was assessed with Gwet's AC. Simulations predicted hyperintensity of lesions with DW-DESS-Cones but at a 3% to 67% lower degree than with DWI. Motion artifacts were reduced with DW-DESS-Cones versus DW-DESS-Cartesian (p < 0.05). Lesion-to-fibroglandular tissue signal ratios were not correlated between DW-DESS-Cones and DWI (r = 0.25, p = 0.38). Concordant hyperintensity/hypointensity was observed between DW-DESS-Cones and DWI in 11/14 lesions. DW-DESS-Cones improved sharpness, distortion, and overall image quality versus DWI. DW-DESS-Cones may be able to eliminate motion artifacts in the breast allowing for investigation of higher degrees of steady-state diffusion weighting. Malignant breast lesions in DW-DESS-Cones demonstrated hyperintensity with respect to surrounding tissue without an injection of contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Imagem Ecoplanar , Feminino , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos
15.
Int Forum Allergy Rhinol ; 10(7): 920-925, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32362076

RESUMO

BACKGROUND: External approaches to the frontal sinus such as osteoplastic flaps are challenging because they require blind entry into the sinus, posing risks of injury to the brain or orbit. Intraoperative computed tomography (CT)-based navigation is the current standard for planning the approach, but still necessitates blind entry into the sinus. The aim of this work was to describe a novel technique for external approaches to the frontal sinus using a holographic augmented reality (AR) application. METHODS: Our team developed an AR system to create a 3-dimensional (3D) hologram of key anatomical structures, based on CT scans images. Using Magic Leap AR goggles for visualization, the frontal sinus hologram was aligned to the surface anatomy in 6 fresh cadaveric heads' anatomic boundaries, and the boundaries of the frontal sinus were demarcated based on the margins of the fused image. Trephinations and osteoplastic flap approaches were performed. The specimens were re-scanned to assess the accuracy of the osteotomy with respect to the actual frontal sinus perimeter. RESULTS: Registration and surgery were completed successfully in all specimens. Registration required an average of 2 minutes. The postprocedure CT showed a mean difference of 1.4 ± 4.1 mm between the contour of the osteotomy and the contour of the frontal sinus. One surgical complication (posterior table perforation) occurred (16%). CONCLUSION: We describe proof of concept of a novel technique utilizing AR to enhance external approaches to the frontal sinus. Holographic AR-enhanced surgical navigation holds promise for enhanced visualization of target structures during surgical approaches to the sinuses.


Assuntos
Realidade Aumentada , Seio Frontal , Cirurgia Assistida por Computador , Seio Frontal/diagnóstico por imagem , Seio Frontal/cirurgia , Humanos , Imageamento Tridimensional , Retalhos Cirúrgicos/cirurgia , Tomografia Computadorizada por Raios X
16.
Ann Thorac Surg ; 110(1): 290-295, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32145195

RESUMO

PURPOSE: Identifying small lung lesions during minimally invasive thoracic surgery can be challenging. We describe 3-dimensional mixed-reality visualization technology that may facilitate noninvasive nodule localization. DESCRIPTION: A software application and medical image processing pipeline were developed for the Microsoft HoloLens to incorporate patient-specific data and provide a mixed-reality tool to explore and manipulate chest anatomy with a custom-designed user interface featuring gesture and voice recognition. EVALUATION: A needs assessment between engineering and clinical disciplines identified the potential utility of mixed-reality technology in facilitating safe and effective resection of small lung nodules. Through an iterative process, we developed a prototype employing a wearable headset that allows the user to (1) view a patient's original preoperative imaging; (2) manipulate a 3-dimensional rendering of that patient's chest anatomy including the bronchial, osseus, and vascular structures; and (3) simulate lung deflation and surgical instrument placement. CONCLUSIONS: Mixed-reality visualization during surgical planning may facilitate accurate and rapid identification of small lung lesions during minimally invasive surgeries and reduce the need for additional invasive preoperative localization procedures.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Realidade Aumentada , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adenocarcinoma/cirurgia , Humanos , Neoplasias Pulmonares/cirurgia , Software , Procedimentos Cirúrgicos Torácicos
17.
IEEE Trans Haptics ; 13(1): 159-166, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31976906

RESUMO

Limited physical access to target organs of patients inside an MRI scanner is a major obstruction to real-time MRI-guided interventions. Traditional teleoperation technologies are incompatible with the MRI environment and although several solutions have been explored, a versatile system that provides high-fidelity haptic feedback and access deep inside the bore remains a challenge. We present a passive and nearly frictionless MRI-compatible hydraulic teleoperator designed for in-bore liver biopsies. We describe the design components, characterize the system transparency, and evaluate the performance with a user study in a laboratory and a clinical setting. The results demonstrate % difference between input and output forces during realistic manipulation. A user study with participants conducting mock needle biopsy tasks indicates that a remote operator performs equally well when using the device as when holding a biopsy needle directly in hand. Additionally, MRI compatibility tests show no reduction in signal-to-noise ratio in the presence of the device.


Assuntos
Retroalimentação Sensorial , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Robótica , Percepção do Tato , Fenômenos Biomecânicos , Biópsia por Agulha , Desenho de Equipamento , Humanos
18.
Magn Reson Med ; 83(5): 1596-1607, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31593337

RESUMO

PURPOSE: To resolve the motion-induced phase variations in multi-shot multi-direction diffusion-weighted imaging (DWI) by applying regularization to magnitude images. THEORY AND METHODS: A nonlinear model was developed to estimate phase and magnitude images separately. A locally low-rank regularization (LLR) term was applied to the magnitude images from all diffusion-encoding directions to exploit the spatial and angular correlation. In vivo experiments with different resolutions and b-values were performed to validate the proposed method. RESULTS: The proposed method significantly reduces the noise level compared to the conventional reconstruction method and achieves submillimeter (0.8mm and 0.9mm isotropic resolutions) DWI with a b-value of 1,000  s/mm2 and 1-mm isotropic DWI with a b-value of 2,000  s/mm2 without modification of the sequence. CONCLUSIONS: A joint reconstruction method with spatial-angular LLR regularization on magnitude images substantially improves multi-direction DWI reconstruction, simultaneously removes motion-induced phase artifacts, and denoises images.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética , Artefatos , Movimento (Física)
19.
Breast Cancer ; 27(3): 405-414, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31838725

RESUMO

BACKGROUND: To evaluate imaging characteristics, outcome of surgical excision or imaging follow-up on high-risk lesions diagnosed at MRI-guided vacuum-assisted breast biopsy (MRI-VABB). METHODS: We retrospectively reviewed 598 lesions undergoing 9-gauge MRI-VABB from January 2015 to April 2018 to identify high risk breast lesions. We collected patient demographics, breast MRI BI-RADS descriptors, histopathological diagnosis at MRI-VABB and surgical excision, frequency of upgrade to malignancy and imaging follow-up of high-risk lesions. The x2 test and Fisher exact tests were performed for univariate analysis. RESULTS: 114 patients with 124/598 findings (20.7%) had high-risk lesions at MRI-VABB, including atypical ductal hyperplasia (ADH) (21/124, 16.9%), lobular neoplasia (40/124, 32.3%), radial scar/complex sclerosing lesion (RS/CSL) (13/124, 10.5%), papillary lesions (49/124, 39.5%), and flat epithelial atypia (FEA) (1/124, 0.8%). 84/124 (67.7%) high-risk lesions were excised. 19/84 (22.6%) were upgraded to malignancy (7 invasive cancer, 12 DCIS). The upgrade rate for ADH and lobular neoplasia was 7/18 (38.9%) and 9/31 (29.0%), respectively. The upgrade rate for RS/CSL was 1/10 (10%). Of the 25 papillary lesions excised, 2 (8%) demonstrated pathologic atypia and were upgraded to DCIS. The other 23 papillary lesions had no upgrade or atypia. Excised high-risk lesions showing upgrade varied from 0.4 to 6 cm in length (mean 1.6 cm). There was a non-significant trend (p = 0.054) between larger lesion and upgrade to malignancy; however, there were no other specific imaging features to predict malignancy upgrade. CONCLUSIONS: There were no specific MRI imaging characteristics of high-risk lesions to predict malignancy upgrade. Therefore, surgical excision is recommended for high-risk lesions, especially ADH or lobular neoplasia.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Lobular/patologia , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Carcinoma Intraductal não Infiltrante/cirurgia , Carcinoma Lobular/cirurgia , Feminino , Seguimentos , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Invasividade Neoplásica , Prognóstico , Estudos Retrospectivos , Vácuo , Adulto Jovem
20.
J Breast Imaging ; 2(2): 141-146, 2020 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38424890

RESUMO

OBJECTIVE: Fibrocystic change (FCC) is considered one of the most common benign findings in the breast and may be commonly seen on breast MRI. We performed this study to identify MRI characteristics of pure FCC on MRI-guided vacuum-assisted breast biopsy (VABB) without other associated pathologies and describe the findings on MRI follow-up and outcomes. METHODS: A retrospective review was performed for 598 lesions undergoing 9-gauge MRI-guided VABB at our institution from January 2015 to April 2018, identifying 49 pure FCC lesions in 43 patients. The associations between variables and lesion changes on follow-up MRI were analyzed using exact Mann-Whitney tests and Fisher's exact tests. RESULTS: MRI features of pure FCC are predominantly clumped nonmass enhancement (19/49, 39%) or irregular masses with initial fast/late washout kinetics (9/49, 18%). There was no upgrade to high-risk or cancerous lesions among the 11 patients (25.6%) who underwent surgery. There were 22 pure FCC lesions in 19 (44.2%) patients who had follow-up MRI (mean 18.0 months, range 11-41 months) showing regression (13, 59%), stability (8, 36%), or progression (1, 5%) of the lesion size, and no cancers were found on follow-up at the site of the MRI biopsy for fibrocystic changes. No patient demographics or lesion features were associated with lesion regression or stability (P > 0.05). CONCLUSION: Our study shows that MRI features of VABB-proven FCC lesions may mimic malignancy. After VABB of pure FCC, given that adequate sampling has been performed, a 12-month follow-up MRI may be reasonable.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...